Hive: Difference between revisions
No edit summary |
No edit summary |
||
(45 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== | == TODO == | ||
* run mh-setup-samba everywhere | |||
* | ** x cast | ||
* | ** x bandit | ||
* | ** glam | ||
* update kodi shares to remove old, add mine | |||
** x cast | |||
** case (needs kodi update) | |||
* update windoze mapped drive to point to mine/mack (get it to persist, ffs) | |||
* move tv-mind, film to mine, pull them out of bitpost, harvest (they are 4 and 6TB!!) | |||
* SHIT i should have burn-tested the drives!!! I AM SEEING ERRORS!! And I won't be able to fix once i have them loaded up... rrr... the true burn tests are destructive... since i'm an impatient moron, i will just have to do SMART tests from TrueNAS UI... | |||
da10 SHORT: SUCCESS | |||
da13 SHORT: SUCCESS | |||
(keep going) | |||
== Pools == | |||
{| class="wikitable" | {| class="wikitable" | ||
! Pool | ! Pool | ||
Line 21: | Line 23: | ||
! Drives | ! Drives | ||
|- | |- | ||
|grim | |grim | ||
|7.2 TB | |7.2 TB | ||
| style="color:red" |raid0 | | style="color:red" |raid0 | ||
|3.64 TB ssd x2 | |3.64 TB ssd x2 | ||
|- | |- | ||
| | |mine | ||
| | |43 TB | ||
| style="color:green" |raidz | |||
|8TB ssd x7 | |||
|- | |||
|safe | |||
|5.2 TB | |||
| style="color:green" |raidz | | style="color:green" |raidz | ||
|1 TB ssd x7 | |1 TB ssd x7 | ||
|} | |} | ||
NOTE that there is an eighth 8TB drive matching the mine array in [[Bluto]]. Harvest it from there if one of the 7 dies. | |||
== Hardware == | |||
* LSI 8-drive SAS board passed through proxmox to hive as "PCI Device": | * LSI 8-drive SAS board passed through proxmox to hive as "PCI Device": |
Latest revision as of 16:31, 8 October 2023
TODO
- run mh-setup-samba everywhere
- x cast
- x bandit
- glam
- update kodi shares to remove old, add mine
- x cast
- case (needs kodi update)
- update windoze mapped drive to point to mine/mack (get it to persist, ffs)
- move tv-mind, film to mine, pull them out of bitpost, harvest (they are 4 and 6TB!!)
- SHIT i should have burn-tested the drives!!! I AM SEEING ERRORS!! And I won't be able to fix once i have them loaded up... rrr... the true burn tests are destructive... since i'm an impatient moron, i will just have to do SMART tests from TrueNAS UI...
da10 SHORT: SUCCESS da13 SHORT: SUCCESS (keep going)
Pools
Pool | Capacity | Type | Drives |
---|---|---|---|
grim | 7.2 TB | raid0 | 3.64 TB ssd x2 |
mine | 43 TB | raidz | 8TB ssd x7 |
safe | 5.2 TB | raidz | 1 TB ssd x7 |
NOTE that there is an eighth 8TB drive matching the mine array in Bluto. Harvest it from there if one of the 7 dies.
Hardware
- LSI 8-drive SAS board passed through proxmox to hive as "PCI Device":
- 7 1 TB Crucial SSDs
Plugged in to SATA 1, 2, 3 and U.2 1, 2, 3, 4. NOTE: to get U.2 drives to be recognized by Melange ASUS mobo required a BIOS change:
Bios > advanced > onboard devices config > U.2 mode (bottom) > SATA (NOT PCI-E)