My server rack: Difference between revisions
No edit summary  | 
				No edit summary  | 
				||
| Line 57: | Line 57: | ||
Update:  | Update:  | ||
* x pull toggle-off power strip from wall, plug into APS550 Surge  | * x pull toggle-off power strip from wall, plug into APS550 Surge  | ||
* mount CyberPower and plug into wall  | * x mount CyberPower and plug into wall  | ||
* update and shut down Bitpost, unplug, plug into CP-UPS, turn on, fix IP as needed, etc.  | * x update and shut down Bitpost, unplug, plug into CP-UPS, turn on, fix IP as needed, etc.  | ||
* check power consumption and adjust plan  | * check power consumption and adjust plan  | ||
* update and shut down melange, unplug, plug into CP-UPS, turn on  | * update and shut down melange, unplug, plug into CP-UPS, turn on  | ||
| Line 64: | Line 64: | ||
* update and shut down cast, unplug, plug into CP-UPS, turn on  | * update and shut down cast, unplug, plug into CP-UPS, turn on  | ||
* check power consumption and adjust plan  | * check power consumption and adjust plan  | ||
* pull APS550 from wall  | * pull APS550 from wall, plug into CP Surge  | ||
* fix IP as needed etc  | |||
* pull always-on-ups strip from APS 750W, plug into APS550 UPS  | * pull always-on-ups strip from APS 750W, plug into APS550 UPS  | ||
* pull APS750 from APS550, harvest battery, mark battery, SMASH APS750  | * pull APS750 from APS550, harvest battery, mark battery, SMASH APS750  | ||
Revision as of 23:38, 31 August 2024
I picked up my server rack from some local guy that seemed to be selling off an abandoned server farm, I think in Morrisville.
Power
- CyberPower OR700LCDRM1U UPS 700VA/400W
 - APC Back-UPS E S 550 550VA/330W
 
Power consumption
| Component | PSU | CyberPower capacity | 
|---|---|---|
| Bitpost | 750W | 30%? | 
| Melange | 750W | 30%? | 
| Cast | 750W | 30%? | 
| Bluto | 1050W | 45%, 135% when gaming (overloaded, constant beeping) | 
| Toggle-off power strip | - | 40% fully loaded with Sony Logitech etc. | 
| Sony 65" TV | - | 37% | 
| Logitech 7.1 amped speakers | - | 3% | 
Layout
- CyberPower
- UPS
- Bitpost
 - Melange
 - Cast
 
 - Surge
- APS Back-UPS ES 550W
- UPS
- Google 2Gb floor cable modem
 - Google 2Gb wall cable modem
 - Always-on power strip
- Server rack fans
 - TP-Link TL-SG1024 24-port gigabit switch
 - Asus AC1300 wireless router
 - Ageen mega USB hub
 
 
 - Surge
- Bluto
 - Toggle-off power strip
- Sony 65" TV
 - Logitech 7.1 amplified speakers
 - KVM hub
 
 
 
 - UPS
 
 - APS Back-UPS ES 550W
 
 - UPS
 
HISTORY
- Prev APS Back-UPS 750 ES UPS: melange, cast, Always-On-Ups strip (usb hub, server case fan, asus router, tplink switch)
 - Prev APS Back-UPS 750 ES Surge: Always-On-Surge strip
 - Prev APS 750 was plugged into APS 550 surge
 
Update:
- x pull toggle-off power strip from wall, plug into APS550 Surge
 - x mount CyberPower and plug into wall
 - x update and shut down Bitpost, unplug, plug into CP-UPS, turn on, fix IP as needed, etc.
 - check power consumption and adjust plan
 - update and shut down melange, unplug, plug into CP-UPS, turn on
 - check power consumption and adjust plan
 - update and shut down cast, unplug, plug into CP-UPS, turn on
 - check power consumption and adjust plan
 - pull APS550 from wall, plug into CP Surge
 - fix IP as needed etc
 - pull always-on-ups strip from APS 750W, plug into APS550 UPS
 - pull APS750 from APS550, harvest battery, mark battery, SMASH APS750